Impact Factors on Removal of Perchloroethylene with Nano-Ni/Fe Methodology
DOI:
Author:
Affiliation:

Clc Number:

P595

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Chlorinated hydrocarbons are widely detected in groundwater, but conventional removal methodologies are not time-and-cost effective. With the development of iron reducing technology in recent years, research on nano-iron and nano-bimetal has become a hot spot. The paper presents the results of impact factors on perchloroethylene (PCE) removal by nano-Ni/Fe method. The data show that the reaction rate of unexposed nano-Ni/Fe is 4 times higher than exposed one; and temperature is one of the important controlling factors. Reaction rate constant KSA increases by 2-3 times with every 10℃ increment of temperature. Within a specific range, higher Ni/Fe ratio favors dechlorination process. When the Ni/Fe is 8%, the dechlorination process reaches the highest rate. Dissoved oxygen in the solution does not favor the degradation of chlorinated hydrocarbons.

    Reference
    Related
    Cited by
Get Citation

LIU;Fei;HUANG;Yuanying;CUI;Weihua.2006. Impact Factors on Removal of Perchloroethylene with Nano-Ni/Fe Methodology[J]. Acta Geologica Sinica(),80(2):262-266