Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
Author:
Affiliation:

Fund Project:

We thank Nicolas Dauphas for providing the OL-Ti standard and Zhang Zhaofeng for providing the AGV-1. This study was financially supported by the National Natural Science Foundation of China (Project Nos. 41473005, 41973020; 41873027). We are grateful to Wen Hongli for analysis of column eluates.

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    Abstract:

    Ti separation was achieved by ion-exchange chromatography using Bio-Rad AG 1-X8 anion-exchange and DGA resins. For high-Fe/Ti and high-Mg/Ti igneous samples, a three-column procedure was required, whereas a two-column procedure was used for low-Fe/Ti and low-Mg/Ti igneous samples. The Ti isotopes were analysed by MC-ICP-MS, and instrumental mass bias was corrected using a 47Ti-49Ti double-spike technique. The 47Ti-49Ti double-spike and SRM 3162a were calibrated using SRM 979-Cr, certificated value 53Cr/52Crtrue = 0.11339. Isobaric interference was evaluated by analysing Alfa-Ti doped with Na, Mg, Ca, and Mo, and results indicate that high concentrations of Na and Mg have no significant effect on Ti isotope analyses; however, Ca and Mo interferences lead to erroneous δ49/47Ti values when Ca/Ti and Mo/Ti ratios exceed 0.01 and 0.1, respectively. Titanium isotopic compositions were determined for 12 igneous reference materials, BCR-2, BHVO-2, GBW07105, AGV-1, AGV-2, W-2, GBW07123, GBW07126, GBW07127, GBW07101, JP-1, and DTS-2b. Samples yield δ49/47Ti (‰) of ?0.035 ± 0.022, ?0.038 ± 0.031, 0.031 ± 0.022, 0.059 ± 0.038, 0.044 ± 0.037, 0.000 ± 0.015, 0.154 ± 0.044, ?0.044 ± 0.018, 0.010 ± 0.022, 0.064 ± 0.043, 0.169 ± 0.034, and ?0.047 ± 0.025 (relative to OL-Ti, ±2SD), respectively; of which isotopic compositions of DTS-2b, JP-1, GBW07101, GBW07105, GBW07123, GBW07126, and GBW07127 are reported for the first time. Standard Alfa-Ti was analysed repeatedly over a ten-month period, indicating a reproducibility of ±0.047 (2SD) for δ49/47Ti, similar to the precisions obtained for geochemical reference materials.

    参考文献
    相似文献
    引证文献
引用本文

LI Jin, TANG Suohan, ZHU Xiangkun, MA Jianxiong, ZHAO Xinmiao.2022. Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method[J]. ACTA GEOLOGICA SINICA(English edition),96(2):517~524

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2020-09-23
  • 最后修改日期:2021-03-13
  • 录用日期:
  • 在线发布日期: 2022-04-25
  • 出版日期: